Denso Power Net Terminal BHT-7500 Spezifikationen Seite 184

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 560
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 183
Chapter 12. Power-related Functions
175
Checking the execution record of remote wakeup
When starting, a user program (including a remote wakeup program) may check via the I/O
ports whether the BHT remotely woke up at the last powering on and its operation was nor-
mally ended. (Refer to Appendix D, "I/O Ports," D5.)
Making use of the execution record, you may display an alarm message.
* This means that the BHT was cold-started, driven by System Mode or initialized.
Port No. Bit 0 Bit 1 Specifications
60F2h 0 0
At the last powering on, the BHT did not remotely
wake up.*
01
1 0 At the last powering on, the BHT remotely woke
up and its operation was interrupted.
1 1 At the last powering on, the BHT remotely woke
up and its operation was normally ended.
Seitenansicht 183
1 2 ... 179 180 181 182 183 184 185 186 187 188 189 ... 559 560

Kommentare zu diesen Handbüchern

Keine Kommentare