Denso RC5 Spezifikationen Seite 84

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 182
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 83
64
3.5.3.10 I/O Read (1010)
(1) Function
This command outputs to the lower 8 bits of the status area the status of the
8-bit internal I/O area starting from the number specified in data area 2.
(2) Format
Command area (4 bits, input)
1010
Data area 1 (8 bits, input)
Nothing will be input.
Data area 2 (16 bits, input)
This is the first number of the internal I/O (8-bit) area whose status will be
output. The number can be set between 128 and 504. If the number is out of
this range, an error (ERROR2034) will occur.
Status area (16 bits, output)
The status of the 8-bit internal I/O area starting from the number specified in
data area 2 will be output to the lower 8 bits of this area.
(3) Description
This command outputs to the lower 8 bits of the status area the status of the
8-bit internal I/O area starting from the number specified in data area 2.
Zero will be output to the upper 8 bits.
Seitenansicht 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 181 182

Kommentare zu diesen Handbüchern

Keine Kommentare