9.4.5 Network Error Indication on DeviceNet Master
The network error display parameter is set to "0: Every Time" by default. It means
that a network error will display every time if it occurs at execution of each I/O
command.
The default is for safe operation of the facilities and is ideal for practical operation.
However, during checking of program operations with dummy I/Os for adjusting
facilities, you need to set this parameter to "1: First Time." Doing so will not display
errors once detected, allowing you to check program operations.
NOTE: After completion of adjustment, be sure to set this parameter back to "0."
Changing the FieldNetwork ErrDisplay parameter
Access: [F4: I/O]—[F6 Aux.]—[F1 Set H/W]
Step 1
In the Auxiliary Function (I/O) window, press [F1 Set H/W].
Step 2
Select "10: FieldNetwork ErrDisplay" and press [F5 Change].
F5