Seitenansicht 193
- 192 -
OffTime
Sets or acquires the OFF duration of the beeper or vibrator.
Syntax
[VB]
Public Property OffTime As Integer
[C#]
public int OffTime{get; set;}
Property
OFF duration of the beeper or vibrator (in units of 100 msec)
Parameter values
: 0 to 255
Default value
: 5
Exceptions
None
Note
If a value outside the permissible range is specified, no exceptions will be thrown
immediately, however, an exception will be thrown later when the start of beeping or
vibrating is specified with an Item property.
If a value other than zero is specified for the ON duration while 0 is specified for the OFF
duration, the beeper or the vibrator will continue to sound or vibrate.
[Ex.] Set the downtime to 1 second.
[VB] MyBeep.OffTime = 10
[C#] MyBeep.OffTime = 10;