250
(4) FNC4
An FNC4 converts data encoded by the code set A or B into a set of extended
ASCII-encoded data (128 added to each official ASCII code value).
A single FN4 character converts only the subsequent data character into the
extended ASCII-encoded data.
A pair of FNC4 characters placed in successive positions converts all of the
subsequent data characters preceding the next pair of FNC4 characters or the stop
character, into the extended ASCII-encoded data. If a single FNC4 character is
inserted in those data characters, however, it does not convert the subsequent
data character only.
An FNC4 character does not convert any of GS characters converted by an FNC1
character, into the extended ASCII-encoded data.
Standard 2 of 5 (STF) (H)
Syntax:
H[:[mini.no.digits[-max.no.digits]][CD] [startstop]
[,[mini.no.digits[-max.no.digits]][CD] [startstop]]
[,[mini.no.digits[-max.no.digits]][CD] [startstop]]]
where
mini.no.digits and max.no.digits are the minimum and maximum numbers of
digits for bar codes to be read by the BHT, respectively.
They should be a numeral from 1 to 99, excluding start/stop characters. They should
satisfy the following condition:
mini.no.digitsmax.no.digits
If both of mini.no.digits and max.no.digits are omitted, then the default
reading range is from the minimum number of digits specified in System Mode up to 99
digits.
If only max.no.digits is omitted, only the number of digits specified by
mini.no.digits can be read.
CD is a check digit. Specifying a C to CD makes the Interpreter check bar codes with
MOD-10. The check digit is included in the number of digits.
startstop specifies the normal or short format of the start/stop characters.
Specify N for the normal format; specify S for the short format. If startstop is
omitted, start/stop characters can be read in either format.
OPEN "BAR:"AS #1 CODE "H:6-12"