Denso BHT-202Q Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 407
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
2. Development Procedure
2.1. Project Creation Procedure
When using Visual Studio .NET 2003
1. Store the dedicated BHT class library (dll, xml file) located in the v1.0\folder in a suitable folder in the
computer used for development.
2. Start up Visual Studio.
3. Select [File] – [New] – [Project…] to create a new project.
4. At the [New Project] dialog box, set the [Project Types:] to “Visual Basic Projects” or “Visual C# Projects”,
and the [Templates] to “Smart Device Application”.
5. At the [Smart Device Application Wizard], set the [What platform do you want to target?] to “Windows CE “,
and the [What project type do you want to create?] to the actual project type to be created.
6. Open the [View] – [Solution Explorer] window.
7. Right-click the [Reference] icon, and select [Add References…] to start up the reference add menu.
8. Press [Browse…] and select the dll saved at step 1.
When using Visual Studio 2005
1. Store the dedicated BHT class library (dll, xml file) located in the v2.0\folder in a suitable folder in the
computer used for development.
2. Start up Visual Studio.
3. Select [File] – [New] – [Project…] to create a new project.
4. At the [New Project] dialog box, set the [Project Types:] to “Visual Basic Projects” or “Visual C# Projects”–
“Smart Device Application”– "Windows CE 5.0", and set the [Template] to the project which you want to
make.
5. Open the [View] – [Solution Explorer] window.
6. Right-click the project name created at step 3 displayed at the [Solution Explorer] window, and select [Add
References…] to start up the reference add menu.
7. Press [Browse…] and select the dll saved at step 1.
2.2. Assignment Procedure
Assignment using Visual Studio .NET 2003 and USB ActiveSync
1. Select [Tools] – [Options…] – [Device Tools] – [Devices] to start up the Device Tool.
2. Press [Save As…] with "Windows CE" selected at the [Show devices for platform:] and enter an
appropriate filename (e.g., “BHT AS”).
3. With the “BHT AS” file created at step 2 selected, set [Transport:] to “TCP Connect Transport”.
4. Press [Configure…] to open the “Configure TCP/IP Transport Settings” dialog box.
5. Select “Obtain an IP address automatically using ActiveSync” for the device IP address.
6. Press [OK] to exit the [Options] menu.
7. Connect the BHT and computer with the USB ActiveSync cable.
1
Seitenansicht 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 406 407

Kommentare zu diesen Handbüchern

Keine Kommentare