Checking the execution record of remote wakeup
When starting, a user program (including a remote wakeup program) may check via the I/O
ports whether the BHT remotely woke up at the last powering on and its operation was nor-
mally ended. (Refer to Appendix D, "I/O Ports.)
Making use of the execution record, you may display an alarm message.
*This means that the BHT was cold-started, driven by System Mode, or initialized.
Port No. Bit 0 Bit 1 Specifications
60F2h 0 0 At the last powering on, the BHT did not remotely
wake up.*
01
1 0 At the last powering on, the BHT remotely woke
up and its operation was interrupted.
1 1 At the last powering on, the BHT remotely woke
up and its operation was normally ended.
Seitenansicht 171