Chapter 12 Robot Control Statements
12-53
CURDEC (System Variable)
Function
Gets the current internal composite deceleration of joints included in a
currently held arm group.
Format
CURDEC
Explanation
Executing this command in a task holding no arm group will return a value of
100.
Related Terms
ACCEL, DECEL, CURACC, CURJACC, CURJDEC, CURJSPD, CURSPD
Example
Ex1 DIM lf1 As Single
lf1 = CURDEC 'Assigns the current deceleration value to lf1.
DECEL CURDEC * 0.5 'Sets the deceleration to 50% of the current value.
Ex2(extended-joint)
PROGRAM PRO1
TAKEARM 1 'Get Arm Group 1.
DECEL 70 'Specify composite deceleration of joints included
'in Arm Group 1 at 70.
I0=CURDEC 'Return current deceleration 70 of Arm Group 1 to I0.
END