21-84
Note (7): The shape of the window available to designate is a rectangle
with 0 degrees. If you designate any shape other than this, an
error occurs.
Note (8): The processing object is the screen designated with
VISWORKPLN.
Note (9): When this command is executed, the process screen 3
(VISWORKPLN 3) is used as a work area and data on the
process screen 3 are not guaranteed. Also, you cannot use
the process screen 3 for processing.
Note (10): You can obtain data with the processing result obtaining
function after executing an instruction.
Note (11): µ
µµ
µVision board (optional) is required for this command.
Note (12): If the searching mode size and the widow size coincide, the
correspondence degree only at that position is calculated.
Note (13): An angles measurement is executed when you set both [Start
Angle] and [End Angle] to 0.
Note (14): An angle measurement is executed as you set as [Start
Angle] = 0 and [End Angle] = 360, if you set both [Start Angle]
and [End Angle] to the same value other than 0.
VISSTATUS (n)
n Item
0 Execution Result
0 = Normal
-1 = Model Unregistered
-2 = Failure
-3 = Timeout
1 Number
2 Execution Time
VISGETNUM (a, b
b a = 0~49
0 Number
1 X Coordinate Value
2 Y Coordinate Value
3 Correspondence Degree
4 Angle [V1.4 or later]
5 X Coordinate Value for
Origin [V1.4 or later]
6 Y Coordinate Value for
Origin [V1.4 or later]
7 Angle from Angular Origin
[V1.4 or later]
8 unknown
9 unknown
Kommentare zu diesen Handbüchern