228
BHT-825Q series
QR code cell pitch dimensions Valid reading distance
0.20 mm
0.25 mm
0.33 mm
0.50 mm
45 to 95 mm *1
40 to 120 mm *1
35 to 150 mm *1
30 to 195 mm *2
PCS value: 0.9 min., White reflection intensity: 85% min
*1
Under the following conditions:
QR code model 2 Ver.5 (37 cells × 37 cells)
Error-correcting level: M,
Black & white label
*2
Under the following conditions:
QR code model 2 Ver.3 (29 cells × 29 cells)
Error-correcting level: M, Black & white
label
Barcode module dimensions Valid reading distance
0.15 mm
0.25 mm
0.33 mm
50 to 95 mm *3
50 to 155 mm *4
30 to 195 mm *5
PCS value: 0.9 min., White reflection intensity: 85% min
*3
Under the following conditions:
Codabar 10 digits NarrowBar, NarrowSpace
0.15mm
*4
Under the following conditions:
Codabar 10 digits NarrowBar, NarrowSpace
0.25mm
*5
Under the following conditions:
EAN-8 Module dimensions 0.33mm
The BHT-825Q series may fail to read codes due to specular reflection depending upon the position of the
light source, reading angle of the reading window, and other conditions.