Set the decode level (code reading tolerance level).
Press [
] to decrease the setting value and [ ] to increase the setting value.
Decode level entry range: 1 - 9 (default: 4)
Setting a lower value improves the reading rate but increases the risk of incorrectly reading poor quality
codes (split or dirty codes). Conversely, setting a higher value reduces the reading rate but decreases the
risk of such errors.
“4: OPTION DATA”
If set to ON when 2D codes are read, option data for the 2D codes such as the model and the
error-correcting level are added to the end of the reading data.
- Point - These settings are enabled even when system mode scanning tests are not being carried
out. Do not change these settings unless necessary.
Option data formats
QR code
N+1 N+2 N+3 N+4 N+5 N+6 N+7
1 2 3 N—1 N
“Q”
Model Version
Error-correcting
level
Mask
(Ex.) When scanned code is “QR code, Model 2, Version 5, Error-correcting level M, Mask number 6”
(Reading data)... Q2v05M6
iQR CODE
n+1 n+2 n+3 n+4 n+5 n+6 n+7
1 2 3 n-1 n
Symbol
type
Version
Error-correcting
level
Mask
(Ex.) When scanned code is “iQR code, oblong figure, Version3, Error-correcting level M, Mask number
0” (Reading data)... G1R03M0
PDF417
N+1 N+2 N+3 N+4 N+5 N+6 N+7 N+8
1 2 3 N—1 N
“Y”
Model
Error-correcting
level
Lines Digits
(Ex.) When scanned code is “PDF417 code, Error-correcting level 4, Lines: 12, Digits: 2” (Reading data)...
Y1041202
MaxiCode
N+1N+2
1 2 3 N—1 N
“X”
Mode
(Ex.) When scanned code is “Maxi code, Mode 4” (Reading data)... X4
Reading data
Option data
Reading data
Option data
Reading data
Option data